. 亚洲国产精品无码久久久久久曰,久久久精品国产亚洲成人满18免费网站,99久久综合狠狠综合久久最近高清影院免费观看,国产亚洲美日韩AV中文字幕无码成人,无码国产亚洲日韩国精品视频一区二区三区
EN CN
Central Venous Catheter

The ABLE? Central Venous Catheters (CVC) are sterile, single-use only polyurethane catheters designed to facilitate infusion therapy in a critical care environment. They are available in variety of lumen configurations, lengths, French and Gauge sizes. The multi lumen variants provide dedicated lumens for infusion therapy, pressure monitoring and venous sampling. The CVC are packaged along with the components and accessories for insertion with Seldinger technique. All products are sterilized by ethylene oxide.

  • Intended Use

  • Contraindications

  • Complications

  • Order Information

  • SSCP


The ABLE® Central Venous Catheters may be applicable to the one of following therapy:

-  Monitor of central venous pressure;

-  Continuous or discontinuous venous transfusion;

-  Blood sampling.



The Catheter is surgically penetrated into three optional puncture points depended on the clinical requirement with Seldinger Technique. The Insertion Sites are :


1. Internal jugular vein; 
2. Subclavian vein; 
3. Femoral vein.

It is possible to be inserted inside the body for no more than 30days. If duration exceeds 30 days, it may occur the risk of combining the catheter and inside tissue, which result in serious incident.



1. Infection or cut wound around the puncture area.

2. Dysfunction of blood coagulation.

3. During the anticoagulant treatment.

4. Symptoms of inadaptability to puncture operation, such as Pneumothorax, vein sclerosis.

5. Abnormal or unclear anatomical situation at the penetration area, such as sever emphysema, obviously inadaptability from previous operation.


The clinical benefit of the use of CVC’s must be evaluated against the recognized risks and complications of the procedure which include but are not limited to:
1. Infection, necrosis of the puncture point
2. Thrombus
3. Extravasation injury
4. Pheumothorax
5. Bleeding/hematoma
6. Arterial puncture
7. Air embolism
8. Hemothorax
9. Cardiac arrhythmia
10. Occlusion


Number of Lumen

O.D.

Effective Length / mm

Ga / Fr

mm

Single

14Ga

2.00

    130, 150, 160, 200, 300

16Ga

1.70

    100, 130, 150, 160, 200, 300

18Ga

1.40

    50, 60, 80, 100, 130, 150, 160, 200, 300

20Ga

1.15

    50, 60, 80, 100, 130, 150, 160, 200

22Ga

0.90

50, 60, 80, 100, 130, 150, 160, 200

24Ga

0.65

50, 60, 80,100,130

Double

4Fr

1.40

50, 60, 80, 100, 120, 130, 150, 160, 200, 250, 300

5Fr

1.70

50, 60, 80, 100, 120, 130, 150, 160, 200, 250, 300

7Fr

2.40

50, 80, 100, 130, 150, 160, 200, 250, 300, 450, 600

8Fr

2.70

100, 130, 150, 160, 200, 300

8.5Fr

2.85

   130, 160, 200, 300

Triple

4.5Fr

1.50

50, 60, 80, 100, 120, 130, 150, 160, 200, 250, 300

5.5Fr

1.85

50, 60, 80, 100, 120, 130, 150, 160, 200, 250, 300

7Fr

2.40

50, 80, 100, 130, 150, 160, 200, 250, 300, 450, 600

8.5Fr

2.85

100, 130, 150, 160, 200, 250, 300

Quad

8.5Fr

2.85

100, 130, 150, 160, 200, 300


The major components of the product package include central venous catheters, guidewire, dilator and puncture needle, etc.

For more information, please contact your sales representative or call +86-757-89959515.